Posted in

How to increase internal circulation in IC tank?

If you’re running an industrial wastewater treatment plant (WWTP) that uses an IC anaerobic tank, odds are you’ve run into that annoying slump in performance: sluggish biogas production, inconsistent sludge mixing, and tank volumes that feel like they’re doing half the work they should. As a supplier who’s worked with dozens of plants on tuning their IC tanks, I get it—internal circulation isn’t just a “nice-to-have” feature, it’s the backbone of how these tanks break down organic matter, keep bacteria happy, and avoid costly process hiccups. Let’s cut to the chase and break down what actually moves the needle when you’re looking to boost that circulation—no stuffy jargon, just real lessons from the field. IC Anaerobic Tank

First, let’s do a quick recap for anyone who might be new to IC systems, because if you don’t grasp the basics, you can’t fix the gaps. The IC (Internal Circulation) anaerobic tank works on a clever loop: biogas produced in the lower, high-loading zone lifts a mix of wastewater, sludge, and gas up through a central riser pipe. That mix then splits at the top—biogas gets captured for energy, and the rest gets recycled back to the bottom of the tank to mix with incoming raw wastewater. That recycle is your internal circulation; weak it, and you get dead zones where sludge settles, bacteria go dormant, and organic loading rates drop.

I’ve seen plants where circulation is off by 10% and they’re only hitting 60% of their biogas output. It’s not rocket science, but it does require checking a few key parts first. Let’s start with the one people usually overlook: the riser pipe and gas separator efficiency.

A lot of older IC tanks have riser pipes that are either too narrow, or the gas separator at the top is caked with old sludge and biofilm. Think about it: the whole circulation loop depends on that biogas lift creating enough pressure to pull the mixed liquor up. If the separator is clogged, it can’t strip all the gas out of that rising mix before it recycles, so you end up with air bubbles in the return line that disrupt the flow. I worked with a food processing plant a few months back—their circulation rate had dropped 25% because their separator was 80% covered with thick, rotting sludge. A 2-hour high-pressure clean on the separator, and a swap of their original 100mm riser for a 125mm pipe (they could fit it without a full tank tear-out) boosted circulation by 20% almost overnight. Pro tip: Don’t just clean the separator once a year—add a quarterly visual check to your maintenance list. If you see thick, crusty buildup, clean it before it starts choking your flow.

Next up, the recirculation pump. Wait, I know, pumps seem obvious, but so many plants either use the wrong pump or let their existing one wear out to the point it’s not pushing enough flow. Here’s the thing: IC tank internal circulation isn’t just about flow rate—it’s about consistent flow. A lot of operators size their recirc pump for peak incoming load, but if the load drops, they leave the pump running at full throttle, which causes cavitation. Cavitation creates those tiny air bubbles I mentioned earlier, which erode pump impellers over time and mess with the suction head needed for the lift. I’ve seen pumps that were only 5 years old have impellers worn down so much they were pushing 30% less flow. A quick pump audit—checking impeller condition, suction pressure, and flow rate against your design specs—can save you a lot of hassle. Also, consider variable frequency drives (VFDs) if you don’t have them already. VFDs let you adjust pump speed to match your incoming wastewater load, so you’re not wasting energy or straining the system. One of my customers in the brewery space switched to VFDs and saw their circulation stability jump 15% while cutting their pump energy use by 22%—win-win.

Then there’s the incoming wastewater distribution system, and this is where dead zones start to form. The IC tank’s bottom zone is where all the action happens—anaerobic bacteria feast on incoming organics, but if that incoming water is just dumping in one or two spots, you’re only mixing a small area. The rest of the tank is stagnant, sludge settles, and circulation can’t pull from those dead spots. I recently worked with a municipal WWTP that had their influent line plumbed into a single 6-inch pipe at the bottom. We added a modular distribution manifold (not a big, expensive retrofit) with 12 evenly spaced outlets, and within 3 weeks, their circulation rate climbed 18%. Why? Because now every corner of the lower zone is getting fresh wastewater, so the biogas production is uniform across the tank, which means the lift is consistent throughout the riser. Side note: If your tank has a multi-stage design (like some of the larger IC systems do), make sure each stage’s distribution is separate. Don’t mix the effluent from the top stage into the incoming feed for the bottom stage— that disrupts the density gradient that drives circulation.

Don’t sleep on sludge inventory management either. Over time, excess anaerobic sludge builds up in the tank, right? And too much sludge can act like a blanket, slowing down the rising mix in the riser and blocking the return flow. I had a customer in the textile industry that was wasting sludge only once a year, and their MLSS (mixed liquor suspended solids) were at 18 g/L—way too high for optimal circulation. We adjusted their wasting schedule to pull 5-10% of excess sludge every week, and within 2 months, MLSS dropped to 12 g/L, and circulation improved 12%. The sweet spot for IC tanks is usually 8-15 g/L MLSS, but that can shift a bit depending on your organic load. Just keep an eye on it—if your sludge is thick and compact, it’s probably holding your system back.

Now, a few common myths I hear all the time, to clear the air. First myth: “Bigger riser pipes = more circulation.” Not necessarily. If your separator is clogged, a bigger riser might just move more of that messy, gas-filled mix, but you’ll still get poor separation at the top. It’s a chain—all links have to be strong. Second myth: “Circulation rate doesn’t matter as long as biogas is being produced.” No, biogas is a result of good circulation, not the other way around. If you’re only making 0.5 m³ of biogas per kg of COD (chemical oxygen demand), that’s a sign your circulation is too low—good IC tanks hit 0.6-0.8 m³/kg. Third myth: I can just blast the recirc pump to fix it. Over-pumping can cause the riser mix to rise too fast, which doesn’t give the gas separator enough time to strip biogas, so you’re recirculating too much gas instead of mixed liquor. That leads to less effective mixing in the bottom zone, which actually lowers biogas production.

Last, let’s talk about when you might need a little extra help from the supplier side. If you’ve checked all these boxes, tuned your maintenance, and adjusted your load, but circulation is still off, it might be a design tweak specific to your tank. A lot of older IC tanks were built with smaller risers or undersized separators that can’t handle the higher loads plants are dealing with now (thanks to tighter wastewater regulations). We work with plants to do tank retrofits that don’t require full replacement—modular riser extensions, upgraded gas separators, and distribution manifold retrofits that fit into existing tanks without major construction. I’ve had customers go from barely hitting 50% circulation to 90% with these targeted tweaks, and it’s saved them hundreds of thousands of dollars compared to buying a new tank.

At the end of the day, boosting internal circulation in your IC tank is all about matching the flow to your actual operation, not just what the design specs say. It’s regular checks, small adjustments, and not ignoring the small parts that make the loop work. If you’re troubleshooting and not sure where to start, don’t guess—reach out. Whether you’re looking for a maintenance tune-up, a retrofit, or just someone to walk through your current system, we’re here to help you get the most out of your IC tank.

MBR Curtain Membrane References:

  1. Metcalf & Eddy. (2014). Wastewater Engineering: Treatment and Reuse, 5th Edition. McGraw-Hill Education.
  2. Tchobanoglous, G., Burton, F. L., & Stensel, H. D. (2003). Anaerobic Treatment Processes. In Wastewater Engineering: Treatment, Disposal, and Reuse (4th ed.). McGraw-Hill.
  3. Environmental Protection Agency (EPA). (2004). Anaerobic Tank Design and Operation for Industrial Wastewater. EPA Office of Water.
  4. International Water Association (IWA). (2019). Internal Circulation (IC) Reactors: Principles, Design and Operation. IWA Publishing.
  5. Water Environment Federation (WEF). (2018). Operation of Anaerobic Treatment Systems. WEF Press.

Jinan Guangbo Environmental Protection Technology Co., Ltd.
We’re well-known as one of the leading ic anaerobic tank manufacturers and suppliers in China. With a professional production team, we are able to meet the needs of the majority of our customers. Please feel free to buy high quality ic anaerobic tank from our factory.
Address: No.102, Commercial and Residential Building, 18th Floor, Tangye Academician Valley, Tangye Sub-district, Licheng District, Jinan City
E-mail: info@gbwwt.com
WebSite: https://www.gbwwt.com/